DocumentCode :
3717990
Title :
Field test and performance analysis of Integrated Cathodic Protection Monitors
Author :
Gyoutae Park;Seung-lak Kim;Seung-ho Han;Geun-jun Lyu;Yeon-jae Lee
Author_Institution :
Institute of Gas Safety R&
fYear :
2015
Firstpage :
1417
Lastpage :
1420
Abstract :
In this paper, we developed and tested comparison performance of our developed Integrated Cathodic Protection Monitor (ICPM) with other instruments. ICPM is more accurate than other products due to using high impedances(100MO) to fit high soil specific resistances. And we achieved measuring of corrosion protection voltages at the fields and comparing of those data with other instruments. We demonstrated our ICPM more excellent than other products through experiments.
Keywords :
"Voltage measurement","Iron","Sea measurements","Lead","Junctions","Anodes"