DocumentCode :
3718558
Title :
MGy Radiation Assessment of a Space-Graded Amplifier and ADC
Author :
Ying Cao;Jens Verbeeck;Marco Van Uffelen;Laura Mont Casellas;Carlo Damiani;Emilio Ruiz Morales;Roberto Ranz Santana;Richard Meek;Bernhard Haist;Wouter De Cock;Ludo Vermeeren;Michiel Steyaert;Paul Leroux
Author_Institution :
Div. LRDMAGyICS, KU Leuven, Heverlee, Belgium
fYear :
2015
Firstpage :
1
Lastpage :
3
Abstract :
This paper shows a high total dose radiation assessment on a set of space qualified components. Two space graded COTS (Commercial off-the-shelf) components were selected and monitored under 60Co gamma radiation, namely an instrumentation amplifier and a 14 bit analogue-to-digital-converter (ADC). The specifications of these COTS components were monitored on-line with a customized test bed, up-to a total ionizing dose larger than 1 MGy and are presented in this paper.
Keywords :
"Sensors","Instruments","Radiation effects","Monitoring","Annealing","Aerospace electronics","Temperature measurement"
Publisher :
ieee
Conference_Titel :
Radiation and Its Effects on Components and Systems (RADECS), 2015 15th European Conference on
Print_ISBN :
978-1-5090-0232-0
Type :
conf
DOI :
10.1109/RADECS.2015.7365633
Filename :