DocumentCode :
3720513
Title :
Technical issues of sizing Lead-Acid batteries for application in residential renewable energy systems
Author :
Mohammad Jafari;Glenn Platt;Zahra Malekjamshidi;Jian Guo Zhu
Author_Institution :
Faculty of Engineering and Information Technology, University of Technology Sydney, PO Box 123, Broadway, NSW 2007, Australia
fYear :
2015
Firstpage :
1
Lastpage :
6
Abstract :
Lead acid batteries are one of the most commonly used storage devices in residential renewable energy systems. This paper explains the procedure of calculating required capacity of lead acid battery for a residential based renewable energy system. A renewable energy system (RES) is introduced based on a topology of multi-port converter. The basic required stored energy is defined using averaged load energy demand and renewable energy generation profiles. The required capacity of lead-acid battery is calculated on the basis of required stored energy considering technical factors such as battery efficiency, operation temperature and number of autonomy days. The technical issues of using Lead Acid batteries are discussed and presented based on the factory provided manuals.
Keywords :
"Batteries","Lead","Renewable energy sources","Ports (Computers)","Smart grids","Electrodes"