• DocumentCode
    3720628
  • Title

    Differences in reverberation chamber insertion loss measurement in time & frequency domian

  • Author

    Hong Lei;Shen Bowen;Zhou Zhongyuan;Zhou Xiang

  • Author_Institution
    Aviation Key Laboratory of Science and Technology on Electromagnetic Environmental Effects, Shenyang, China
  • fYear
    2015
  • Firstpage
    148
  • Lastpage
    151
  • Abstract
    Differences in the insertion loss of a reverberation chamber as measured in frequency & time domain are shown. And an alternative approach for measuring the insertion loss which is named as time domain energy-decay method is proposed, and compared with conventional time domain time-decay method & frequency domain continuous wave based method. Insertion loss measured by time domain energy-decay method is identical to that which would be obtained in frequency domain. The insertion loss determined by time-decay method is 1~2dB greater than those obtained with frequency domain measurement, the main reason for the discrepancy is the influence of antenna (antenna impedance mismatch and non-unit antenna efficiency). The effectiveness of the time domain method for measuring the insertion loss of a reverberation chamber is of particular interest in this paper.
  • Keywords
    "Antennas","Antenna measurements","Impedance","Computers","Universal Serial Bus"
  • Publisher
    ieee
  • Conference_Titel
    Environmental Electromagnetics (CEEM), 2015 7th Asia-Pacific Conference on
  • Print_ISBN
    978-1-4673-9444-4
  • Type

    conf

  • DOI
    10.1109/CEEM.2015.7368651
  • Filename
    7368651