Abstract
This paper describing about the tool made by author that used to measure the emission of CRT (cathode ray tube) for televisions and monitors, and can be used as a CRT Injector. The purpose of the design and manufacture of this tool is to learn about the emission of electrons on the CRT screen that is on the RGB cathodes are used as part of producing an image that is emitted by an electron gun to the screen. Which is often subject to corrosion. For that this tool has a working principle is to eliminate corrosion on the CRT cathode RGB and balancing of beam electron emission from the RGB cathode that producing image and it will be back as good as usual. This tool can also be used in color or monochrome television monitor and also for oscilloscope. The tool is divided into several blocks, namely heater circuit blocks, cathode injection circuit blocks, measuring tools circuit blocks, and display output injection blocks.
Keywords
"Cathodes","Switches","Heating","Iron","Nickel","Anodes","Electron tubes"