• DocumentCode
    3725012
  • Title

    Development method for paralleling inverters on microgrid when islanding condition using reconfiguration of PV circuit

  • Author

    Hartono Bs;Rudy Setiabudy;Eko Adhi Setiawan; Budiyanto

  • Author_Institution
    Dept. of Energy Conversion Eng., Politek. Negeri Bandung, Bandung, Indonesia
  • fYear
    2015
  • Firstpage
    121
  • Lastpage
    124
  • Abstract
    During islanding conditions, two or more on/off GTIs will work stand alone, these inverters can´t work in parallel, because there is no parallel mechanism in this inverter. So power absorption from PV not reach maximum and battery power drain. To make these inverters can work in parallel we must add a power limiter in input inverter using chopping/PWM method and this is not cheap. This research proposed method to parallel two inverter using reconfiguration of Photovoltaic (PV) circuit on microgrid based on/off GTI inverter, in islanding condition, using master slave parallel network topology inverter. The test results showed paralleling two inverter can be done using reconfiguration of Photovoltaic (PV) circuit and increase the absorption of energy from PV up to 26% and reduce the use of battery backup up to 26.38%, so the level of the battery can be sustained.
  • Keywords
    "Pulse width modulation","Lead","Switches","Inverters","Microgrids","Photovoltaic systems"
  • Publisher
    ieee
  • Conference_Titel
    Quality in Research (QiR), 2015 International Conference on
  • Print_ISBN
    978-1-4799-6550-2
  • Type

    conf

  • DOI
    10.1109/QiR.2015.7374909
  • Filename
    7374909