DocumentCode :
3728036
Title :
An Optimal Diagnosis of NoC Interconnects on Activation of Diagonal Routers
Author :
Biswajit Bhowmik;Santosh Biswas;Jatindra Kumar Deka
Author_Institution :
Dept. of Comput. Sci. &
fYear :
2015
Firstpage :
755
Lastpage :
760
Abstract :
Previous works on detecting and locating manufacturing faults-shorts, stuck-at, and open on an interswitch link of a channel in a network-on-chip (NoC) have been based on the assumption that these faults do not coexist. The works failed to diagnose all these faults when this assumption is relaxed. A deficiency for non-diagnosability of these faults is then represented. A packet address driven test strategy that detects and locates a faulty inters witch link in a NoC channel is proposed. The strategy addresses the intra-channel shorts, stuck at, and open faults coexist on inters witch links and is governed by parallel activation of diagonal routers. The strategy is scalable with mesh NoCs. Simulation results achieve 100% and more than 97% fault coverages when faults are diagnosed explicitly and implicitly respectively.
Keywords :
"Testing","Silicon","Payloads","Routing protocols","Topology","Manufacturing","Adaptive algorithms"
Publisher :
ieee
Conference_Titel :
Systems, Man, and Cybernetics (SMC), 2015 IEEE International Conference on
Type :
conf
DOI :
10.1109/SMC.2015.141
Filename :
7379273
Link To Document :