DocumentCode
3732421
Title
The evaluation of the design and operation of the 400MW evaporative cooling hydrogenerator in LiJiaXia hydropower station
Author
Ruan Lin;Liu Feihui;Gu Guobiao;Wang Xingang;Sun Tianhu
Author_Institution
Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing, 100190
fYear
2015
Firstpage
209
Lastpage
213
Abstract
The 400MW evaporative cooling hydrogenerator in Lijiaxia hydropower station has been serving for more than 15 years. This paper gives a comprehensive evaluation of this unit from cooling mode selection, electrical magnetic scheme design, operating practice and temperature distribution. The application of the evaporative cooling technology to 400MW-grade hydrogenerator shows great advantages comparing with the same capacity air cooling units, which demonstrates the correct of design and the stability and safety of long-term operation.
Keywords
"Cooling","Hydroelectric power generation","Decision support systems","Temperature distribution","Thermal stability","Safety","Maintenance engineering"
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
Type
conf
DOI
10.1109/ICEMS.2015.7385028
Filename
7385028