DocumentCode
3732700
Title
An arc fault detection system for the household photovoltaic inverter according to the DC bus currents
Author
Kun Xia;Zihui He;Yin Yuan;Yiming Wang;Po Xu
Author_Institution
School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, China
fYear
2015
Firstpage
1687
Lastpage
1690
Abstract
An arc fault detection system for household photovoltaic inverter according to the DC bus currents was discussed in the paper. A current transformer was employed to capture currents of the DC bus. The detected signals were filtered by a band-pass filter to derive the meaningful waves. TMS320F28062 DSP was selected as the master chip. It accomplished the fast Fourier transform in chip and gave the pattern recognition for the frequency spectrum of the arc. It will disconnect the inverter from the DC bus when an arc fault is diagnosed. The proposed system has been successfully applied to detect the arc fault of the household photovoltaic inverter reliably.
Keywords
"Inverters","Photovoltaic systems","Band-pass filters","Fault detection","Decision support systems","Current transformers"
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
Type
conf
DOI
10.1109/ICEMS.2015.7385312
Filename
7385312