DocumentCode
3732725
Title
Single-phase grid-connected PV system supplying nonlinear load with MPPT
Author
Prakit Liengpradis;Vijit Kinnares
Author_Institution
Department of Electrical Power Engineering, Faculty of Engineering, King Mongkut´s Institute of Technology Ladkrabang, Bangkok, Thailand
fYear
2015
Firstpage
1836
Lastpage
1839
Abstract
This paper presents a single-phase grid-connected PV system supplying nonlinear load which controls active power and harmonic compensation. The control method employs calculated reference current derived from a combination between the active current and the compensated harmonic current. The active current for controlling transferred power from solar panels to the grid system is obtained from MPPT. The compensated harmonic current is responsible for nonlinear load. With this method, power of renewable energy can be transferred to nonlinear load and the utility grid system, the grid current can be a noticeable sinusoidal and the reactive power of nonlinear load will be compensated. As a result, power factor is nearly unity. The simulation results confirm the validation through MATLAB/Simulink for both steady state and dynamic response conditions.
Keywords
"Decision support systems","Harmonic analysis","Renewable energy sources","Reactive power","Power system harmonics","Solar panels"
Publisher
ieee
Conference_Titel
Electrical Machines and Systems (ICEMS), 2015 18th International Conference on
Type
conf
DOI
10.1109/ICEMS.2015.7385339
Filename
7385339