DocumentCode :
3733167
Title :
Improved condition monitoring system to protect railway axle bearing safety from electric corrosion
Author :
F.Q. Yuan;J.M. Lu
Author_Institution :
Department of Engineering and Safety, University of Troms? - The Arctic University of Norway, Norway
fYear :
2015
Firstpage :
1634
Lastpage :
1638
Abstract :
Axle bearing is a critical machine element in the railway system to the operation reliability and safety in the transportation. The failure of the axle bearing can lead to derailment. In order to assure the transportation safety, this paper discusses the cause of the axel bearing failure, and proposes the counter measurement to reduce the risk. Due to the failure of previous implemented counter-measurement, this paper suggest implementing the condition monitoring system to monitor the axle bearing, aiming to confine the bearing failure in control. In order to improve the failure diagnosis accuracy, this paper suggests collecting signal from various perspectives, for example, vibration, current, voltage, temperature etc. on the axle bearing for the condition monitoring system. The various signals should be analysed by using physical model and data driven model, for the maintenance policy optimization.
Keywords :
"Corrosion","Condition monitoring","Axles","Rail transportation","Current","Current measurement","Safety"
Publisher :
ieee
Conference_Titel :
Industrial Engineering and Engineering Management (IEEM), 2015 IEEE International Conference on
Type :
conf
DOI :
10.1109/IEEM.2015.7385924
Filename :
7385924
Link To Document :