DocumentCode :
3736753
Title :
Illumination, phase step optimization and improvements in simultaneous multiple frequency measurement for Time-of-Flight sensors
Author :
Vinh Nguyen Xuan;Wolfgang Weihs;Otmar Loffeld
Author_Institution :
Center for Sensorsystems, University of Siegen, Germany
fYear :
2015
Firstpage :
1
Lastpage :
6
Abstract :
The systematic linearity error due to harmonics present in a Time-of-Flight (TOF) sensor system contributes to the inaccuracy of its three dimensional (3D) depth measurements. In this paper, a modified method which combines illumination waveform optimization and phase stepping algorithm selection is proposed to achieve a better performance at measurement linearity through numerical and practical experiment. Additionally, a solution of high-order harmonic reduction in simultaneous multiple frequency framework is investigated for unambiguous range and acceptable high frame rate.
Keywords :
"Linearity","Lighting","Harmonic analysis","Frequency measurement","Sensors","Demodulation","Optimization"
Publisher :
ieee
Conference_Titel :
3D Imaging (IC3D), 2015 International Conference on
Type :
conf
DOI :
10.1109/IC3D.2015.7391811
Filename :
7391811
Link To Document :