DocumentCode :
3741695
Title :
Evaluation of a head movement artifact removal method for EEG considering real-time prosessing
Author :
Kazuki Onikura;Keiji Iramina
Author_Institution :
Graduate school of Information Science and Electrical Engineering, Kyushu University, Fukuoka, Japan
fYear :
2015
Firstpage :
1
Lastpage :
4
Abstract :
The present study proposes the method of removing head movement artifact for considering real-time processing and improving reliability of EEG under unconstrained measurement. In the proposed method, independent component analysis and high-pass filtering were used with a hybrid accelerometer, which was used for detecting components containing head movement artifact. To evaluate the proposed method, we measured EEG which included the artifact and P300 components. As a result, although EEG amplitude decreased, original P300 waveform appeared clearly. This result indicates that the proposed method is effective for removing head movement artifact while keeping EEG information.
Keywords :
"Electroencephalography","Accelerometers","Electrodes","Magnetic heads","Head","Real-time systems","Pollution measurement"
Publisher :
ieee
Conference_Titel :
Biomedical Engineering International Conference (BMEiCON), 2015 8th
Type :
conf
DOI :
10.1109/BMEiCON.2015.7399577
Filename :
7399577
Link To Document :
بازگشت