DocumentCode
3745412
Title
Research on Non-contact Optical Measurement Methods for the Dimension of Inner Diameter
Author
Liu Bo;Li Xiaogang;Wang Mingxing
Author_Institution
Higher Educ. Key Lab. for Meas. &
fYear
2015
Firstpage
239
Lastpage
241
Abstract
Researched a non-contact optical measurement system, in order to meet the requirements for the accurate measurement of the inside dimension of tubular parts, the system mainly consisted of the optical ring generator, the total reflection prism and the CCD camera. Ring laser emitted by the optical ring generator was reflected onto the inner surface, formed a ring spot that its size reflected the inside dimension of tubular parts at a particular cross section, then it was reflected by the gathering prism and formed an image in the photosensitive surface of CCD camera, the inside dimension of tubular parts could be obtained by processing and calculating the image. Experiment showed that the system could efficiently and quickly measure the inside dimension of tubular parts, simultaneously, could ensure the high precision.
Keywords
"Optical variables measurement","Optical imaging","Optical reflection","Charge coupled devices","Cameras","Adaptive optics"
Publisher
ieee
Conference_Titel
Instrumentation and Measurement, Computer, Communication and Control (IMCCC), 2015 Fifth International Conference on
Type
conf
DOI
10.1109/IMCCC.2015.57