• DocumentCode
    3745412
  • Title

    Research on Non-contact Optical Measurement Methods for the Dimension of Inner Diameter

  • Author

    Liu Bo;Li Xiaogang;Wang Mingxing

  • Author_Institution
    Higher Educ. Key Lab. for Meas. &
  • fYear
    2015
  • Firstpage
    239
  • Lastpage
    241
  • Abstract
    Researched a non-contact optical measurement system, in order to meet the requirements for the accurate measurement of the inside dimension of tubular parts, the system mainly consisted of the optical ring generator, the total reflection prism and the CCD camera. Ring laser emitted by the optical ring generator was reflected onto the inner surface, formed a ring spot that its size reflected the inside dimension of tubular parts at a particular cross section, then it was reflected by the gathering prism and formed an image in the photosensitive surface of CCD camera, the inside dimension of tubular parts could be obtained by processing and calculating the image. Experiment showed that the system could efficiently and quickly measure the inside dimension of tubular parts, simultaneously, could ensure the high precision.
  • Keywords
    "Optical variables measurement","Optical imaging","Optical reflection","Charge coupled devices","Cameras","Adaptive optics"
  • Publisher
    ieee
  • Conference_Titel
    Instrumentation and Measurement, Computer, Communication and Control (IMCCC), 2015 Fifth International Conference on
  • Type

    conf

  • DOI
    10.1109/IMCCC.2015.57
  • Filename
    7405836