DocumentCode :
3745581
Title :
Design and Analysis of Static Pressure Distribution and Measurement on Contact Interface
Author :
Zhuo-Fu Liu;Guang-Sheng Xi;Lin Wang;Zhongming Luo;Yongbo Li
Author_Institution :
Higher Educ. Key Lab. for Meas. &
fYear :
2015
Firstpage :
1050
Lastpage :
1054
Abstract :
The developed human body-seat surface pressure measurement system is rational and feasible, and can measure the human body and the pressure distribution dynamically and in real time. The human body seat surface pressure distribution measurement system mainly includes FSR pressure sensor array and STC15F2K60S2 microcontroller. First, the standard weight scale is used to calibrate the FSR sensor and draw the output voltage curve under different pressure inputs. STC15F2K60S2 microcontroller has eight 10-bits AD converters. System adopts RS232 serial interface with the PC for serial communication. The MATLB is employed to conduct data processing and analysis, while the band pass filter is applied for noise suppression. After filtering data in the pre-processing stage, Fourier transform is used to analyze the valid data, then use SP Tool tools for simulation.
Keywords :
"Pressure measurement","Band-pass filters","Pressure sensors","Analog-digital conversion","Digital filters","IIR filters","Surface treatment"
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement, Computer, Communication and Control (IMCCC), 2015 Fifth International Conference on
Type :
conf
DOI :
10.1109/IMCCC.2015.227
Filename :
7406006
Link To Document :
بازگشت