DocumentCode :
3747649
Title :
Investigation of single-switch short-circuit fault characteristics of a PM machine drive with a current source inverter
Author :
Yichao Zhang;Wanjun Zhang;T. M. Jahns
Author_Institution :
University of Wisconsin - Madison, WEMPEC, Dept. of Elec. & Computer Eng., Madison, WI USA 53706
fYear :
2015
fDate :
5/1/2015 12:00:00 AM
Firstpage :
967
Lastpage :
973
Abstract :
This paper investigates the single-switch short-circuit fault response of a permanent magnet (PM) machine drive using a current source inverter (CSI). The CSI offers some appealing advantages over conventional voltage-source inverters (VSIs) during short-circuit fault conditions originating inside the inverter. Two post-fault strategies are investigated in this paper, consisting of either: 1) turning off all of the switches; or 2) turning on all of the switches in a controlled manner. Key features associated with the machine response to both of these post-fault strategies are presented and compared, leading to the conclusion that both make it possible to protect the machine. A combination of analysis, simulation, and experimental tests has been adopted for carrying out this investigation.
Keywords :
"Circuit faults","Inverters","Capacitors","Transient analysis","Resonant frequency","Rotors","Switches"
Publisher :
ieee
Conference_Titel :
Electric Machines & Drives Conference (IEMDC), 2015 IEEE International
Type :
conf
DOI :
10.1109/IEMDC.2015.7409178
Filename :
7409178
Link To Document :