DocumentCode
374795
Title
Monte Carlo investigation of scatter in dual head coincidence imaging
Author
Pointon, B.W. ; Sossi, V.
Author_Institution
Dept. of Phys., British Columbia Inst. of Technol., Burnaby, BC, Canada
Volume
2
fYear
2000
fDate
2000
Abstract
Scatter is a major problem in dual head coincidence imaging using 3D acquisition. We investigated the scatter response in an ADAC Vertex MCD camera using Monte Carlo simulations. Simulations of different cylindrical phantoms were done to compare with measured values. These show agreement in the relative scatter fraction distribution but underestimate the magnitude of the scatter. The simulation bins by number of scatters to allow the relative contribution from single and multiple scatter to be determined. Results for the NEMA scatter phantom yield global multiple scatter fractions (multiple over total scatter) of 16% in p-p mode and 29% in p-C mode, which do not vary axially. Simulations of a digital anthropomorphic phantom were then done to assess scatter in clinical situations. These showed global scatter fractions 37% to 48% in p-C acquisition for different activity distributions and positioning, significantly higher than from cylindrical phantoms. The global multiple scatter fractions were also higher for the anthropomorphic phantom with values from 31% to 48% in p-C mode. The distributions from the anthropomorphic phantom also showed that the scatter fractions and multiple scatter fractions varied axially and with source distribution and positioning. The characterization of scatter is valuable in guiding scatter correction strategies
Keywords
Compton effect; Monte Carlo methods; biomedical equipment; gamma-ray scattering; image reconstruction; medical image processing; positron emission tomography; 3D acquisition; ADAC Vertex MCD camera; Monte Carlo simulation; NEMA scatter phantom; cylindrical phantoms; dedicated PET; digital anthropomorphic phantom; dual head coincidence imaging; multiple scatter; relative scatter fraction distribution; scatter correction strategies; scatter magnitude; scatter response; single scatter; Anthropomorphism; Cameras; Detectors; Electromagnetic scattering; Imaging phantoms; Magnetic heads; Monte Carlo methods; Particle scattering; Physics; Positron emission tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Nuclear Science Symposium Conference Record, 2000 IEEE
Conference_Location
Lyon
ISSN
1082-3654
Print_ISBN
0-7803-6503-8
Type
conf
DOI
10.1109/NSSMIC.2000.950006
Filename
950006
Link To Document