• DocumentCode
    374798
  • Title

    Crosstalk and scatter correction in simultaneous dual isotope SPECT imaging using four energy windows method

  • Author

    Paek, M.Y. ; Lee, J.S. ; Lee, D.S. ; Chung, J.-K. ; Lee, M.C.

  • Author_Institution
    Dept. of Nucl. Med., Seoul Nat. Univ., South Korea
  • Volume
    2
  • fYear
    2000
  • fDate
    2000
  • Abstract
    One of the limitations of the simultaneous dual isotope SPECT with Tc-99m and I-123 is the crosstalk of the photons from one radionuclide to the other radionuclide´s photopeak, which is serious since the difference between the photopeak of Tc-99m and I-123 is small (140 keV, 159 keV). We designed a method for correcting this crosstalk effect using four energy windows, by which we could reduce the effect of scatter as well as crosstalk. We also validated our method by comparing the corrected images to the single-isotope image acquired with phantom study. After defining the energy windows for each isotope, crosstalk fractions from the photopeak of one isotope to the photopeak/scatter windows of the other isotope were determined. Using these fractions, the effect of scatter and crosstalk was compensated. Relative errors were estimated between the single and the crosstalk/scatter corrected dual isotope images. Measured crosstalk fractions did not change regardless of the activity of each isotope. Contamination of activity was reduced as a result of crosstalk correction (CC), and image contrast was improved by scatter correction (SC). Relative errors decreased further after SC on CC images. Using four energy windows method, we could obtain a more accurate result in simultaneous dual isotope SPECT
  • Keywords
    crosstalk; gamma-ray scattering; image reconstruction; image registration; medical image processing; single photon emission computed tomography; crosstalk correction; crosstalk fractions; four energy windows method; image contrast; phantom study; photon crosstalk; photopeak; relative errors; scatter correction; simultaneous dual isotope SPECT imaging; Contamination; Crosstalk; Design methodology; Electromagnetic scattering; Error correction; Imaging phantoms; Isotopes; Particle scattering; Pollution measurement; Single photon emission computed tomography;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.950010
  • Filename
    950010