• DocumentCode
    374822
  • Title

    A dynamic expectation maximization algorithm for single camera rotation dynamic SPECT (dSPECT)

  • Author

    Farncombe, T. ; Blinder, S. ; Celler, A. ; Noll, D. ; Maeght, J. ; Harrop, R.

  • Author_Institution
    Dept. of Phys., British Columbia Univ., Vancouver, BC, Canada
  • Volume
    2
  • fYear
    2000
  • fDate
    2000
  • Abstract
    A new dynamic SPECT reconstruction algorithm is presented that is able to estimate the dynamic behaviour of activity within an object from projection data acquired with a conventional single slow rotation of a SPECT camera. The algorithm is based on the static expectation maximization (EM) reconstruction algorithm, but incorporates dynamic inequality constraints in the reconstructed object voxel activity over time to account for dynamic behaviour. This method has previously been presented in the constrained least squares (CLS) dynamic SPECT method which uses an optimization technique to minimize a dynamic objective function. A series of simulated dynamic object projection data sets have been reconstructed with the new dynamic EM algorithm (dEM) and results compared to the CLS method of dynamic image reconstruction. Results of these tests indicate that the dEM algorithm is able to produce time activity curve parameters that are within 20% of the true values, while improving upon reconstruction time by a factor of 2-3 times compared to the CLS method. Further experiments have been performed using the authors´ dynamic heart-in-thorax phantom and have implemented both attenuation and depth dependent detector response corrections. Results indicate a similar degree of accuracy when reconstructed with the dEM algorithm, with again an improvement in reconstruction time of between 2-3 times
  • Keywords
    cardiology; image reconstruction; medical image processing; optimisation; rotation; single photon emission computed tomography; constrained least squares dynamic SPECT method; depth dependent detector response corrections; dynamic expectation maximization algorithm; dynamic heart-in-thorax phantom; medical diagnostic imaging; nuclear medicine; optimization technique; reconstruction time improvement; simulated dynamic object projection data sets series; single camera rotation dynamic SPECT; time activity curve parameters; Attenuation; Cameras; Constraint optimization; Detectors; Heuristic algorithms; Image reconstruction; Imaging phantoms; Least squares methods; Reconstruction algorithms; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium Conference Record, 2000 IEEE
  • Conference_Location
    Lyon
  • ISSN
    1082-3654
  • Print_ISBN
    0-7803-6503-8
  • Type

    conf

  • DOI
    10.1109/NSSMIC.2000.950042
  • Filename
    950042