• DocumentCode
    3749015
  • Title

    Reliability Loss with Sampling Rate Reduction

  • Author

    Paulo Sousa;Rute Almeida;Marta Jo?o Silva;Ana Paula Rocha

  • Author_Institution
    Faculdade de Ci?ncias, Universidade do Porto, Portugal
  • fYear
    2015
  • Firstpage
    689
  • Lastpage
    692
  • Abstract
    High sampling frequency is not usually available in hospital monitoring systems, what can limit the usefulness of the data, namely for repolarization measures. In this work the reliability of beat-to-beat measures using low sampling frequency is quantified with respect to the original high sampling rate. ECG recordings originally at 1000 Hz, including intensive care patients data, were downsampled to 500 Hz and to 250 Hz. Automatic delineation was applied to extract beat-to-beat intervals. The reliability was measured considering concordance correlation coefficient (CCC) and intraclass correlation coefficient (ICC); the Information-based measure of disagreement (IBMD) was used for agreement quantification. High reliability and low disagreement were generally found. Using the conventional interpretation excellent consistency was found at 250 HZfor more than 68%, 50%, 50% and 58% of the cases for RR, RT, QT and QTc, respectively. Results indicate that at 250 Hz RR, RT, QT and QTc measures are still reliable compared with the values at 1000 Hz.
  • Keywords
    "Frequency measurement","Reliability","Electrocardiography","Correlation","Indexes","Lead"
  • Publisher
    ieee
  • Conference_Titel
    Computing in Cardiology Conference (CinC), 2015
  • ISSN
    2325-8861
  • Print_ISBN
    978-1-5090-0685-4
  • Electronic_ISBN
    2325-887X
  • Type

    conf

  • DOI
    10.1109/CIC.2015.7411004
  • Filename
    7411004