DocumentCode :
3749198
Title :
Electrocardiogram signal enhancement using an efficient Sign Regressor error normalized variable step size adaptive algorithm
Author :
Gowri T.; Rajesh Kumar P.
Author_Institution :
Dept. of ECE, GIT, GITAM University, Visakhapatnam-530045, A.P, INDIA
fYear :
2015
Firstpage :
343
Lastpage :
347
Abstract :
The pre processing analysis is most important in the Electrocardiogram (ECG) signal. In order to preprocess the signal quality we used an efficient block based error normalized variable step size adaptive algorithm. Using this algorithm the ECG artifacts can be minimized. In this paper we considered power line Interference and baseline wander artifacts of ECG signal. We also obtained other algorithms from the block based error normalized algorithms: those are Sign Regressor, Sign Error and Sign Sign Block based algorithms, because of these algorithms give less computational complexity. The performance of the signal is evaluated and calculated signal to noise ratio, plotted convergence characteristics. By the observation of noise cancellation in power line interference the Sign Regressor variable step size algorithm performs better. The ability of the filter is checked by collecting ECG signal from MIT-BIH database.
Keywords :
"Electrocardiography","Adaptive algorithms","Algorithm design and analysis","Signal processing algorithms","Signal to noise ratio","Adaptive filters","Steady-state"
Publisher :
ieee
Conference_Titel :
Computing and Network Communications (CoCoNet), 2015 International Conference on
Type :
conf
DOI :
10.1109/CoCoNet.2015.7411208
Filename :
7411208
Link To Document :