DocumentCode :
3749491
Title :
Experimental apparatus for breakdown phenomena study in dielectric material under high hydrostatic pressure
Author :
Hoang The-Giam;P. Guerin;R. Lacoste;L. Deschamps;J. Perret
Author_Institution :
LABORATOIRE DE GENIE ELECTRIQUE (CNRS LA 304), UNIVERSITE PAUL SABATIER - 118, ROUTE DE NARBONNE, 31062 TOULOUSE (FRANCE)
fYear :
1983
fDate :
7/1/1983 12:00:00 AM
Firstpage :
390
Lastpage :
394
Abstract :
From these results, we can conclude that the measurement of electric strength of dielectrics can be made with our experimental design in the ranges of 1 to 800 bars in pressure, 20°C to 70°C in temperature and 0 to 100 kV in d.c voltage. The breakdown voltage values are given with an appreciable accuracy.
Keywords :
"Temperature measurement","Electric breakdown","Breakdown voltage","Dielectric measurement","Bars","Atmospheric measurements","Detectors"
Publisher :
ieee
Conference_Titel :
Conduction and Breakdown in Solid Dielectrics, Proceedings of First International Conference on
Type :
conf
DOI :
10.1109/ICSD.1983.7411544
Filename :
7411544
Link To Document :
بازگشت