DocumentCode
374996
Title
A detailed analysis of EMI test receiver measurement uncertainty
Author
Stecher, Manfred
Author_Institution
Rohde & Schwarz GmbH & Co. KG, Munchen, Germany
Volume
1
fYear
2001
fDate
2001
Firstpage
464
Abstract
The paper describes how the total uncertainty of an EMI test receiver can be determined from a standardized calibration report. In addition to the three main parameters: absolute level and frequency response, linearity of the detectors and the uncertainty of the step attenuators, many further parameters including the uncertainties of the calibration laboratory´s calibration system are contributing to the total uncertainty. Among these parameters are data on temperature stability obtained from the design engineer, as well as data on internal gain drift between internal gain adjustments obtained from observation. Generally a differentiation has to be made between uncertainty arising from imperfect correction for systematic effects and uncertainty arising from random effects
Keywords
calibration; electromagnetic interference; frequency response; measurement uncertainty; test equipment; EMI test receiver; absolute level; detectors linearity; frequency response; internal gain adjustments; internal gain drift; measurement uncertainty analysis; random effects; standardized calibration report; step attenuators uncertainty; systematic effects; temperature stability data; total uncertainty; Attenuators; Calibration; Detectors; Electromagnetic interference; Frequency response; Laboratories; Linearity; Measurement uncertainty; Temperature; Testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2001. EMC. 2001 IEEE International Symposium on
Conference_Location
Montreal, Que.
Print_ISBN
0-7803-6569-0
Type
conf
DOI
10.1109/ISEMC.2001.950684
Filename
950684
Link To Document