Title :
Simulation of electronic circuit sensitivity towards humidity using electrochemical data on water layer
Author :
Salil Joshy;Vadimas Verdingovas;Morten Jellesen;Rajan Ambat
Author_Institution :
Department of Mechanical Engineering, Technical University of Denmark, 2800 Kgs. Lyngby, Denmark
fYear :
2015
Firstpage :
1
Lastpage :
5
Abstract :
Climatic conditions like temperature and humidity have direct influence on the operation of electronic circuits. The effects of temperature on the operation of electronic circuits have been widely investigated, while the effect of humidity and solder flux residues are not well understood including the effect on circuit and PCBA (printed circuit board assembly) layout design. This paper elucidates a methodology for analyzing the sensitivity of an electronic circuit based on parasitic circuit analysis using data on electrical property of the water layer formed under humid as well as contaminated conditions. Some commonly used circuits are analyzed as case studies and flux related contaminations of PCBA from process is used as an example to show how different flux chemistry and humidity together compromise the circuit functionality.
Keywords :
"Humidity","Regulators","Resistors","Electronic circuits","Water pollution","Soldering","Resistance"