Title :
Current monitoring in power electronic equipment with GTO-thyristors
Author_Institution :
Institute for Power Electronics and Electrical Drives, RWTH Aachen, Technical University, West Germany
fDate :
6/1/1986 12:00:00 AM
Abstract :
The application of GTO-thyristors requires special short-circuit protection equipment. A simple method based on the proportionality of turn-off current and storage time of a GTO is shown to protect GTO-thyristors against turn-off failure during a short circuit. Additionally, this method can be employed for overload protection, failure diagnosis and current monitoring.
Keywords :
"Current measurement","Logic gates","Voltage measurement","Temperature measurement","Anodes","Switches","Time measurement"
Conference_Titel :
Power Electronics Specialists Conference, 1986 17th Annual IEEE
Print_ISBN :
978-9-9963-2327-0
DOI :
10.1109/PESC.1986.7415590