• DocumentCode
    3752369
  • Title

    Space station 20-kHz power management and distribution system

  • Author

    Irving G. Hansen;Gale R. Sundberg

  • Author_Institution
    National Aeronautics and Space Administration, Lewis Research Center, Cleveland, Ohio 44135, United States
  • fYear
    1986
  • fDate
    6/1/1986 12:00:00 AM
  • Firstpage
    676
  • Lastpage
    683
  • Abstract
    During the conceptual design phase a 20-kHz power distribution system was selected as the reference for the space station. The system is single-phase 400 VRMS, with a sinusoidal wave form. The initial user power level will be 75 kW with growth to 300 kW. The high-frequency system selection was based upon considerations of efficiency, weight, safety, ease of control, interface with computers, and ease of paralleling for growth. Each of these aspects will be discussed as well as the associated trade-offs involved. An advanced development program has been instituted to accelerate the maturation of the high-frequency system. Some technical aspects of the advanced development program will be discussed.
  • Keywords
    "Switches","NASA","Resonant frequency","Conductors","Decision support systems","Atmospheric measurements","Particle measurements"
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 1986 17th Annual IEEE
  • ISSN
    0275-9306
  • Print_ISBN
    978-9-9963-2327-0
  • Type

    conf

  • DOI
    10.1109/PESC.1986.7415623
  • Filename