DocumentCode
3752424
Title
New method of decreasing the potential on the oil surface in the tank with the help of an electrostatic screener
Author
M. Fujii;H. Mitera;A. Ohashi;K. Tottori
Author_Institution
Department of Electrical Engineering, Fukui Institute of Technology, Fukui 910, (Japan)
fYear
1984
fDate
7/1/1984 12:00:00 AM
Firstpage
433
Lastpage
437
Abstract
Some discharging effectiveness was found in the oil tank system equipped with 100 or 200 mesh stainless screen fixed on top of the diffuser at the oil inlet. To study the discharging mechanism in detail, the potential distribution along the axis of the cylindrical oil tank, the earth current in each part of the oil-flow system, and surface potential of the oil tank were measured.
Keywords
"Electrostatics","Electric potential","Fuel storage","Current measurement","Earth","Surface discharges","Accidents"