Title :
Total ionizing dose tolerance of the serial configuration on cyclone II FPGA
Author :
Hiroyuki Ito;Minoru Watanabe
Author_Institution :
Electrical and Electronic Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu, Shizuoka 432-8561, Japan
Abstract :
Recently, existing radiation-hardened static random access memory (SRAM)-based field programmable gate arrays (FPGAs) are anticipated for use in space radiation environments. Although such radiation-hardened SRAM-based FPGAs are programmable, the use of a radiation-damaged gate array has never been assessed for use with application-specific integrated circuits (ASICs) because its serial configuration is invariably damaged first by radiation so that the configuration itself becomes impossible. Therefore, currently available FPGA cannot be used in such faulty gate arrays used in space environments. However, if faulty programmable gate arrays are used, then the total ionizing dose tolerance of the programmable gate array would be increased even if its process technology were the same as that of conventional FPGAs. In this paper, in order to explore the possibility, we experimentally assessed the configuration circuit robust capabilities of a normal Cyclone II FPGA. Also, we examined the failure probability when using 1-bit, 2-bit, 4-bit, and 8-bit buses for the FPGA configuration using the designs of serially configured FPGAs.
Keywords :
"Field programmable gate arrays","Logic gates","Cyclones","Programmable logic arrays","Radiation detectors","Circuit faults"
Conference_Titel :
Space Optical Systems and Applications (ICSOS), 2015 IEEE International Conference on
DOI :
10.1109/ICSOS.2015.7425067