DocumentCode :
3758186
Title :
Calculation of no-load saturation curve for wound field synchronous machines based on magnetic equivalent circuits and conformal mapping
Author :
Ana Hanic;Zlatko Hanic;Mario Vrazic;Damir Zarko
Author_Institution :
University of Zagreb, Faculty of Mining, Geology and Petroleum Engineering, Croatia
fYear :
2015
Firstpage :
513
Lastpage :
518
Abstract :
This paper describes a method for calculation of the no-load saturation curve for wound field synchronous machines based on magnetic equivalent circuits and conformal mapping. The method uses conformal mapping to calculate reluctances of the magnetically active parts of the machine which are then used in magnetic equivalent circuit for the calculation of magnetic fluxes. Proposed method is applied to a salient, six-pole, 400 V, 50 Hz synchronous machine with double layered armature winding and obtained results are compared with finite element method.
Keywords :
"Saturation magnetization","Magnetic circuits","Electron tubes","Magnetic flux","Synchronous machines","Conformal mapping","Equivalent circuits"
Publisher :
ieee
Conference_Titel :
Electrical Machines & Power Electronics (ACEMP), 2015 Intl Conference on Optimization of Electrical & Electronic Equipment (OPTIM) & 2015 Intl Symposium on Advanced Electromechanical Motion Systems (ELECTROMOTION), 2015 Intl Aegean Conference on
Type :
conf
DOI :
10.1109/OPTIM.2015.7426979