DocumentCode :
3758577
Title :
Validation of Smartphone Gyroscopes for Angular Tracking in Biofeedback Applications
Author :
Anton Umek;Anton Kos;Sao Tomaic
Author_Institution :
Fac. of Electr. Eng., Univ. of Ljubljana, Ljubljana, Slovenia
fYear :
2015
Firstpage :
294
Lastpage :
298
Abstract :
The paper presents the limitations of smartphone MEMS gyroscopes and their suitability for biofeedback applications with rotation detection. We measured the smartphone gyroscope biases, identified the main causes for gyroscope errors, and quantified their influence on sensor precision. The main validation test includes angular measurements performed concurrently by the calibrated gyroscope and the reference professional optical tracking system. The comparison of both measurement results show, that the existing smartphones with their built-in gyroscopes are sufficiently accurate for angular tracking in real-time biofeedback applications used in sports, recreation, rehabilitation, and wellbeing.