Comparison of predicted and measured oxygen levels in a semi-closed underwater breathing apparatus
Author :
Nuckols, Marshall L. ; Finlayson, W. Scott ; Newville, Brian ; Gavin, W.A., Jr.
Author_Institution :
Ocean Eng. Program, US Naval Acad., Annapolis, MD, USA
Volume :
3
fYear :
2001
fDate :
2001
Firstpage :
1725
Abstract :
An analytical model has recently been developed for predicting the circuit oxygen levels in semi-closed underwater breathing apparatus at various mission depths and diver activity levels (Nuckols, Clarke, Marr, 1999). Unmanned testing in June 2000 with a commercially available US Divers Aqualung OxyMix rebreather (NEDU Test Plan Number 00-06 dated May 2000) showed good agreement with this analytical model over a wide range of diver depths, orientations and activity levels (Nuckols, Gavin, Finlayson, 2000). However, the model indicated that an enhanced performance capability could possibly be achieved with the OxyMix by modifying the size of its exhaust bellows and changing the oxygen content of the supply gas. Following the tests in June, an optimization approach was applied to the analytical model to define desired design parameters for the OxyMix rebreather to maximize its excursion depth capability. Optimized exhaust volume ratios (EVR), the ratio of the small inner bellows volume relative to the main breathing bellows, and supply gas oxygen concentrations were identified to maximize safe operations for the OxyMix design. US Divers agreed to fabricate two modified exhaust bellows of varying volumes for testing to verify the predicted performances of the modified OxyMix rebreather. During the week of 18 December 2000, unmanned testing with these modified OxyMix rebreathers at the Experimental Dive Facility at NEDU verified predicted performances. Specific findings in these tests included a) a modified OxyMix rebreather using an exhaust volume ratio of approximately 6.25% and a supply gas mixture containing 37% oxygen was shown to give an excursion capability to 130 FSW while maintaining circuit PO2 levels below 1.32 Ata (excursions to 150 FSW were shown to be possible with maximum PO2 levels below 1.6 Ata) b) similar to the results seen in the June tests, circuit PO2 levels were shown to be unaffected by diver activity rates between RMV´s of 22.5 LPM and 62.5 LPM c) the addition of a diluent injection system on the modified OxyMix design provided minimum circuit oxygen levels of 0.42 Ata at 20 FSW and 0.25 Ata at 0 FSW while still maintaining circuit PO2 levels below 1.32 Ata for excursions up to 130 FSW
Keywords :
biological techniques; optimisation; oxygen; physiological models; pneumodynamics; Experimental Dive Facility at NEDU; O2; OxyMix rebreather; US Divers; analytical model; breathing bellows; diluent injection system; diver activity levels; measured oxygen levels; minimum circuit oxygen levels; mission depths; optimization approach; optimized exhaust volume ratios; predicted oxygen levels; safe operations maximization; semiclosed underwater breathing apparatus; supply gas mixture; Analytical models; Bellows; Carbon dioxide; Circuit testing; Design optimization; Oxygen; Performance evaluation; Rebreathing equipment; Sea measurements; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
OCEANS, 2001. MTS/IEEE Conference and Exhibition
Conference_Location :
Honolulu, HI
Print_ISBN :
0-933957-28-9
Type :
conf
DOI :
10.1109/OCEANS.2001.968093
Filename :
968093
Link To Document :
بازگشت