DocumentCode :
3759595
Title :
An algorithm for direct 4-D PET image reconstruction/non-rigid motion estimation with limited MRI prior information
Author :
Alexandre Bousse;Jieqing Jiao;Luis Pizarro;Kris Thielemans;David Atkinson;S?bastien Ourselin;Simon Arridge;Brian F. Hutton
Author_Institution :
Institute of Nuclear Medicine, University College London, NW1 2BU, UK
fYear :
2014
Firstpage :
1
Lastpage :
3
Abstract :
MP-JRM performs better in situations where JRM and MRI-IR under-perform. This is because MP-JR relies on both MRI and PET data, whereas JRM and MRI-IR rely on one modality only. In addition, results tend to show that with temporal smoothing on B-spline parameters, a subset of MRI volumes gives enough information to compensate for motion. Further work is in progress to analyse variance and bias as well as reconstruction from real gated data.
Keywords :
"Magnetic resonance imaging","Positron emission tomography","Image reconstruction","Logic gates","Tumors","Estimation","Motion estimation"