• DocumentCode
    3761463
  • Title

    Locked-rotor test methods for induction motors investigated

  • Author

    Robbie McElveen;Mike Melfi

  • Author_Institution
    Baldor Electric Company 6040 Ponders Court Greenville, SC 29615 USA
  • fYear
    2015
  • Firstpage
    1
  • Lastpage
    9
  • Abstract
    Locked-rotor testing is a common end-of-the-line check performed on most motors used in the petrochemical industry. Despite its popularity as a verification of rotor integrity and to confirm the current draw and torque produced at zero speed, there can be much ambiguity in how the test is performed. This test is not required by the National Electrical Manufactures Association Motors and Generators standard (NEMA MG1) or the Institute of Electrical and Electronics Engineers Standard 112 (IEEE 112). IEEE 112 contains a locked-rotor test method, but there can be variations in the results based upon the test conditions (duration of voltage application and magnitude of applied voltage, for instance). The purpose of this paper is to describe how the test procedure employed affects the locked-rotor test results for both current and torque. Model and test data is presented to illustrate the variations possible depending on the test technique.
  • Keywords
    "Induction motors","Rotors","Torque","IEC Standards","Testing","Equivalent circuits"
  • Publisher
    ieee
  • Conference_Titel
    Petroleum and Chemical Industry Committee Conference (PCIC), 2015 IEEE
  • ISSN
    0090-3507
  • Print_ISBN
    978-1-4799-8501-2
  • Electronic_ISBN
    2161-8127
  • Type

    conf

  • DOI
    10.1109/PCICON.2015.7435098
  • Filename
    7435098