DocumentCode
3761804
Title
Automatic removal of auto fluorescence device part using circular hough transform
Author
Muhammad Awais;Ibrahima Faye;Nicolas Walter;Mohamad Naufal Saad
Author_Institution
Centre for Intelligent Signal and Imaging Research, Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Bandar Sen Iskandar, 32610 Tronoh, Perak, Malaysia
fYear
2015
Firstpage
11
Lastpage
15
Abstract
For detection of oral potential malignant disorder (OPMD), devices such as VELscope, are potentially used in the oral cavity examination. The device area usually appears in the acquired images. A preprocessing stage, which consists of removing the device area, is required before the analysis of the images. In this paper we propose a method based on the Circular Hough transform (CHT) to detect auto fluorescence device part in the oral cavity images. The results revealed that the device area is successfully recognized whenever it is present in the image.
Keywords
"Fluorescence","Image edge detection","Transforms","Cavity resonators","Biomedical imaging","Detectors","Shape"
Publisher
ieee
Conference_Titel
Biomedical Engineering & Sciences (ISSBES), 2015 IEEE Student Symposium in
Type
conf
DOI
10.1109/ISSBES.2015.7435878
Filename
7435878
Link To Document