DocumentCode :
3763272
Title :
Influence of rail wear on output voltage of eddy-current rail displacement sensor
Author :
Yoshifumi Shimojima;Yinggang Bu;Tsutomu Mizuno;Takafumi Asahi;Makoto Ito;Shigemi Enoki
Author_Institution :
Faculty of Engineering, Shinshu University, Nagano, Japan
fYear :
2015
Firstpage :
396
Lastpage :
401
Abstract :
This paper describes the structure and output voltage characteristics of a rail displacement sensor comprising triangular coils. The calculation was demonstrated under a few assumptions. The maximum output voltage error between the measured and the calculated values was 2.4%. The influence of rail wear on output voltage leads to a displacement error of 12 mm.
Keywords :
"Rails","Coils","Impedance","Measurement uncertainty","Displacement measurement","Impedance measurement","Capacitance"