• DocumentCode
    3763319
  • Title

    Metrological frequency response analysis of a high current instrument transformer

  • Author

    Christian J?schke;Peter Schegner

  • Author_Institution
    Technische Universit?t Dresden, Germany
  • fYear
    2015
  • Firstpage
    640
  • Lastpage
    645
  • Abstract
    This paper presents the metrological frequency response analysis of a high current instrument transformer (HCT) with a rated primary current of 8 kA. A special measuring system is used to identify the frequency response of the HCT at different primary currents in a frequency range up to 40 kHz. The burden dependency of the frequency response is determined by using different resistive and resistive-inductive burdens. The measuring results indicate the good transmission behaviour of the HCT at higher frequencies by applying resistive burdens. However, resonances occur by applying resistive-inductive burdens, resulting in high resonance peaks which deteriorate the transmission behaviour of the HCT and cause high voltages at its secondary side.
  • Keywords
    "Ribs","Current measurement","Instrument transformers","Couplings","Resonant frequency"
  • Publisher
    ieee
  • Conference_Titel
    Sensing Technology (ICST), 2015 9th International Conference on
  • Electronic_ISBN
    2156-8073
  • Type

    conf

  • DOI
    10.1109/ICSensT.2015.7438476
  • Filename
    7438476