DocumentCode :
376471
Title :
Stability analysis of a synchronous generator with simultaneous AC and rectified DC load
Author :
Qing, Yang ; Weiming, Ma ; Xusheng, Wu ; Junzhong, Sun
Author_Institution :
Res. Inst. of Power Electron. Tech. Application, Naval Univ. of Eng., Wuhan, China
Volume :
1
fYear :
2001
fDate :
2001
Firstpage :
587
Abstract :
An equivalent circuit model of a synchronous generator with simultaneous AC and rectified DC load is presented in this paper. By use of the principle of harmonic balance, which makes it possible to construct a state-space mathematical model of this system the criterion of operation stability is derived for the system under small disturbance. It is shown that the AC load is favorable for improving the system stability and the generator parameters have considerable effects on the system stability. The analytical results are compared with those obtained by simulation and experiment, and good agreements are observed
Keywords :
equivalent circuits; load (electric); machine theory; stability; state-space methods; synchronous generators; AC load; equivalent circuit model; generator parameters; harmonic balance; operation stability; rectified DC load; small disturbance; stability analysis; state-space mathematical model; synchronous generator; AC generators; DC generators; Magnetic circuits; Power electronics; Reactive power; Rectifiers; Rotors; Stability analysis; Sun; Synchronous generators;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2001. ICEMS 2001. Proceedings of the Fifth International Conference on
Conference_Location :
Shenyang
Print_ISBN :
7-5062-5115-9
Type :
conf
DOI :
10.1109/ICEMS.2001.970744