DocumentCode
3764896
Title
A simple non invasive technique for structural health monitoring
Author
Kazi Jabed Akram;Tarikul Islam;Akil Ahmed
Author_Institution
Department of Electrical Engineering, Jamia Millia Islamia, New Delhi, India
fYear
2015
Firstpage
1
Lastpage
4
Abstract
The efficiency of a parallel plate capacitor for the detection of moisture concentration in concrete structure is proposed in this paper. As the presence of moisture in the concrete structure deteriorate the health of the structure, therefore its presence should be correctly examined. In this paper, the effect of moisture on the electrical properties such as impedance, capacitance, phase angle, dissipation factor of concrete is thoroughly studied. A fly ash brick has been taken in order to analyze the performance of the proposed methodology.
Keywords
"Moisture","Concrete","Impedance","Capacitance","Sensors","Electrodes","Dielectric constant"
Publisher
ieee
Conference_Titel
India Conference (INDICON), 2015 Annual IEEE
Electronic_ISBN
2325-9418
Type
conf
DOI
10.1109/INDICON.2015.7443597
Filename
7443597
Link To Document