DocumentCode :
3766957
Title :
Optimal modeling and sizing of a practical standalone PV/battery generation system using numerical algorithm
Author :
Ibrahim A. Ibrahim;Azah Mohamed;Tamer Khatib
Author_Institution :
Department of Electrical, Electronic and Systems Engineering, Universiti Kebangsaan Malaysia, Selangor, Malaysia
fYear :
2015
Firstpage :
43
Lastpage :
48
Abstract :
This paper presents an optimization method for sizing a standalone PV system by considering improved PV array model, dynamic storage battery model, and realistic objective function. The loss of load probability is used to define the availability level of the system. Different PV/battery configurations with different availability levels are generated using the proposed numerical algorithm. These configurations are evaluated based on system availability and cost. Hourly metrological and load demand data are used in this research. The result shows that the optimal sizing ratio of the PV array (CA) is 1.184, while the sizing ratio for battery (CB) is 0.613 and the levelized cost of energy for the unit generated by the proposed system is 0.447 $/kWh.
Publisher :
ieee
Conference_Titel :
Research and Development (SCOReD), 2015 IEEE Student Conference on
Type :
conf
DOI :
10.1109/SCORED.2015.7449372
Filename :
7449372
Link To Document :
بازگشت