DocumentCode :
3767085
Title :
Improvements in AEPD location identification by removing outliers and post processing
Author :
Deepthi Antony;Gururaj S Punekar
Author_Institution :
Department of Electrical and Electronics Engineering, National Institute of Technology Surathkal Karnataka, Mangalore, India
fYear :
2015
Firstpage :
66
Lastpage :
69
Abstract :
The mathematical model of an Acoustic Emission Partial Discharge (AEPD) system is solved in the literature using Newton´s method with redundant number of sensors (more than 4; eight in this case). The system for numerical experiments consists of eight sensors. The algorithm is implemented using three different initial guesses. For the calculated PD source coordinates, histograms are plotted. After finding the mean and standard deviation, coordinate values which are lying outside different fractions of sigma are removed. The average of remaining set is calculated and it is found that, the accuracy of location identification can be greatly improved.
Keywords :
"Partial discharges","Mathematical model","Histograms","Sensor systems","Standards","Acoustic emission"
Publisher :
ieee
Conference_Titel :
Condition Assessment Techniques in Electrical Systems (CATCON), 2015 International Conference on
Type :
conf
DOI :
10.1109/CATCON.2015.7449510
Filename :
7449510
Link To Document :