• DocumentCode
    3770580
  • Title

    Automated testing of high voltage insulation using a micro-processor controlled tangent delta bridge and power supply

  • Author

    George A. Przybys

  • Author_Institution
    Tettex Instruments, Inc., 1055 West Germantown Pike, Fairview Village, Pennsylvania 19409, United States
  • fYear
    1985
  • Firstpage
    129
  • Lastpage
    133
  • Abstract
    Insulation measurements on high voltage equipment are usually performed using a bridge method, comparing the specimen against a known standard. The measuring process involves adjusting the high voltage level, reading a nullindicator, balancing the bridge, transcribing the readings and eventually analyzing the data. This process has been completely automated by means of a micro-processor and a measuring system suitable for high voltage laboratories or assembly line testing is described in this paper.
  • Keywords
    "Voltage measurement","Insulation","Bridge circuits","Dielectric measurement","Generators","Capacitance","Current measurement"
  • Publisher
    ieee
  • Conference_Titel
    Electrical/Electronics Insulation Conference, 1985 EIC 17th
  • Print_ISBN
    978-1-5090-3115-3
  • Type

    conf

  • DOI
    10.1109/EIC.1985.7458593
  • Filename
    7458593