DocumentCode :
3770625
Title :
Effect of intermediate anneal on magnet wire properties of copper wire
Author :
Ramesh Gandhi
Author_Institution :
General Electric Co., Fort Wayne, Indiana, USA
fYear :
1985
Firstpage :
348
Lastpage :
349
Abstract :
In the early period of copper wire drawing, an intermediate annual was routinely performed to relieve stresses in the hard drawn wire. The annealing of copper “breakdown” wire helped make the subsequent drawing operation easier and with a minimum of wire breaks.
Keywords :
"Wires","Annealing","Magnetomechanical effects","Copper","Magnetic properties","Stress","Temperature"
Publisher :
ieee
Conference_Titel :
Electrical/Electronics Insulation Conference, 1985 EIC 17th
Print_ISBN :
978-1-5090-3115-3
Type :
conf
DOI :
10.1109/EIC.1985.7458638