DocumentCode
3770998
Title
A solid state high frequency tester
Author
E. A. Macura;P. F. Pittman;P. A. Sanghavi
Author_Institution
Westinghouse Electric Corporation, Pittsburgh, Pennsylvania, USA
fYear
1971
Firstpage
4
Lastpage
6
Abstract
Although it has been in use for many years, high frequency testing to establish the integrity of coil insulation remains superior to any other known technique. The use of solid-state switching devices to replace the spark gap used by Rylander, and the use of an oscilloscope display in place of his wavemeter have improved considerably the accuracy and reproducibility of the test, and made it more simple and fast. In addition, the procedure of discharging into two parallel coils and displaying the differential current signal has increased the sensitivity of the test. Because it is easily wheeled from place to place, this tester provides a degree of flexibility not available heretofore. For these reasons, the use of this type of apparatus for coil testing should increase markedly in the near future.
Keywords
"Coils","Switches","Insulation","Oscilloscopes","Discharges (electric)","Capacitors","Inductance"
Publisher
ieee
Conference_Titel
Electrical Insulation Conference, 1971 EIC 10th
Print_ISBN
978-1-5090-3116-0
Type
conf
DOI
10.1109/EIC.1971.7460753
Filename
7460753
Link To Document