Title : 
Life testing and screening of high voltage insulation systems for electrical-chemical compatibility
         
        
        
            Author_Institution : 
3M Company, Saint Paul, Minnesota, USA
         
        
        
        
        
            Abstract : 
All aspects of a micaceous insulation system should be considered when determining its usefulness as a mechanical and dielectric barrier. The insulation must be suitable for application to the coil, impregnated with a resin to make the system void free (except for B-stage tape); must exhibit low tan Ii and high dielectric strength as well as good corona resistance; and must withstand the service conditions of coil insertion, vibration, thermal and moisture cycling. In this study we have been primarily concerned with the electrical-chemical compatibility aspects of systems evaluations.
         
        
            Keywords : 
"Insulation","Corona","Stress","Aging","Temperature measurement","Electrodes","Epoxy resins"
         
        
        
            Conference_Titel : 
Electrical Insulation Conference, 1971 EIC 10th
         
        
            Print_ISBN : 
978-1-5090-3116-0
         
        
        
            DOI : 
10.1109/EIC.1971.7460755