DocumentCode :
3771027
Title :
Life VS voltage performance of flat conductor cables & lightweight round wire systems
Author :
N. J. Cotter;J. R. Perkins
Author_Institution :
Plastics Department, E. I. du Pont de Nemours & Co., Inc., Wilmington, Delaware, USA
fYear :
1971
Firstpage :
99
Lastpage :
102
Abstract :
A study has been made to arrive logically at appropriate voltage ratings for unshielded fiat conductor cables and round insulated wires in air. The criterion used is corona starting at sea level and at various altitudes for single and multi-insulation systems. These idealized values depend upon the insulation thickness and dielectric constants. Observed data were in adequate agreement with the calculations. It is concluded that some existing constructions may have been rated at excessively high voltages.