• DocumentCode
    3771029
  • Title

    Commutator fusing

  • Author

    Allan Warner

  • fYear
    1971
  • Firstpage
    109
  • Lastpage
    111
  • Abstract
    Commutator fusing has increased the reliability of the universal and D.C. electric motors. We must still understand that the connection between the armature´s coil and commutator is the weakest link in the entire motor. If we fully understand the theory of commutator fusing very few problems should occur when using it, and this weak link will be a little stronger.
  • Keywords
    "Wires","Commutation","Welding","Heating","Metals","Resistance","Electrodes"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference, 1971 EIC 10th
  • Print_ISBN
    978-1-5090-3116-0
  • Type

    conf

  • DOI
    10.1109/EIC.1971.7460784
  • Filename
    7460784