Title
Sealed tube test techniques for hermetic enamel evaluation
Author
Robert S. Olsen
Author_Institution
General Electric Company, Fort Wayne, Indiana, USA
fYear
1971
Firstpage
119
Lastpage
122
Abstract
The work carried out indicates that the level of moisture sealed into a tube directly affects the rate of formation of decomposition products, such as Refrigerant 22.It is a reasonable assumption that aluminum chloride is formed continuously on the wire. It is not until all the free water becomes chemically combined that anhydrous aluminum chloride can form and begin to catalyze the Refrigerant 22 formation.
Keywords
"Electron tubes","Aging","Wires","Refrigerants","Moisture","Glass","Heating"