Abstract
Under high humidity service or test conditions typified by MIL-E-5272. commercial epoxy-glass circuit laminates degrade in insulation resistance. Leakage currents often increase to values unacceptable for high impedance circuits. Insulation resistance is comprised of two components in parallel: Surface and volume resistance. Surface resistance is usually controlled by cleaning and the use of conformal coatings. Volume resistance has been little studied and is here investigated in some detail.
Keywords
"Resistance","Glass","Humidity","Coatings","Laminates","Electrodes","Surface impedance"