• DocumentCode
    3771183
  • Title

    A new apparatus for the precise measurement of dissipation factor over the frequency range 0.1 to 200 MHz

  • Author

    K A Buckingham

  • Author_Institution
    Imperial Chemical Industries Limited, Plastics Division - Welwyn Garden City, UK
  • fYear
    1979
  • Firstpage
    329
  • Lastpage
    334
  • Abstract
    A new apparatus for the measurement of the dissipation factor of plastics, under factory conditions, over the frequency range 0.1 to 200 MHz is described. Typical repeatability for measurements on low loss materials is within + 0.1 ? rad and the agreement with other measurement systems is ca ? 1 ? radian. Specific new design features are detailed.
  • Keywords
    "Electrodes","Temperature measurement","Frequency measurement","RLC circuits","Loss measurement","Inductors","Capacitors"
  • Publisher
    ieee
  • Conference_Titel
    Electrical/Electronics Insulation Conference, 1979 EIC 14th
  • Print_ISBN
    978-1-5090-3113-9
  • Type

    conf

  • DOI
    10.1109/EIC.1979.7461146
  • Filename
    7461146