• DocumentCode
    3771264
  • Title

    Development of a simulated service test for insulation systems used in turbine-generator rotors

  • Author

    Edward A. Boulter

  • Author_Institution
    Materials and Processes Laboratory, Medium Steam Turbine, Generator & Gear Department, General Electric Company, West Lynn, Massachusetts, USA
  • fYear
    1965
  • Firstpage
    209
  • Lastpage
    212
  • Abstract
    The Generator Rotor Simulated Service Test represents a new and useful method of comparing different slot armor insulation systems in a functional manner. The capability to combine mechanical, electrical and thermal stresses on Iow cost samples of new and aged slot armor constructions has speeded the development and application of new materials. A new type of molded fibrous glass and resin slot armor was shown to be superior and has been successfully adopted for product use. A continuing program of materials evaluation with this facility is underway and yielding valuable data.
  • Keywords
    "Insulation","Rotors","Stress","Aging","Heating","Copper","Generators"
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation Conference, 1965 Sixth
  • Print_ISBN
    978-1-5090-3105-4
  • Type

    conf

  • DOI
    10.1109/EIC.1965.7461229
  • Filename
    7461229